Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery
HomeStore

Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery

Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery

Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery

 

  • LiFePO4 Chemistry - Deep Cycle Battery
  • Group 24: L10.25" x W6.75" x H9.00"
  • Low-Temperature cut-off (Charge Protection)
  • Built-in Smart Battery Management System (BMS)
  • Advanced BMS system with 20+ safety features built in
  • Over charge and over discharge protection
  • Over current and short circuit protection
  • High & low temperature disconnects
  • Max (4) in Series up to 48V
  • Max (16) in Parallel up to 20.48 kWh
  • 4,500+ Cycle life & Maintenance-free
  • 6 Year Manufacturer Warranty

Specifications 

Cell Configuration: 4S1P
Chemistry: LiFePO4
Current
Ah Capacity: 314Ah
Max Continuous Discharge Amps: 250A
Max Charge Current Amps: 250A
Max Discharge Peak Current Amps: 750A (5 Seconds)
Series | Parallel: Max (4) in Series, Max (16) in Parallel
Voltage
Voltage: 12.8V
Max Charge Voltage: 14.6V
Operating Voltage Range: 10.0 - 14.6V
Temperature
Charge Temp Range: 0°C (32°F) / 55°C (131°F)
Discharge Temp Range: -20°C (-4°F) / 60°C (140°F)
Storage Temp: 0°C (32°F) / 35°C (95°F)

Weights & Dimensions

Weight: 57 (LBS)
Dimensions
Length: 13.75" @ Base, 15.5" @ Handles (inches)
Width: 7.63" (inches)
Height: 10.0", 10.5' with Terminal Bolts (inches)
s)

Recommended Charge Settings 

To properly charge your Epoch Batteries, you will want to verify that any charging component in your system is capable of being programmed for the following specifications. Charging components can include, but are not limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.
Bulk/Absorption: 14.2V – 14.6V
Absorption Time: Two batteries in parallel connections require 30 minutes 200Ah
Float: 13.4V – 13.8V
Equalization: 14.4V/ Disabled
Temperature Compensation: 0/Disabled
Charge Rate: 50% of the battery or battery bank capacity
Battery Charge Temperature Range: 32°F (0°C) to 131°F (55°C)
Battery Discharge Temperature Range: -4°F (-20°C) to 140°F (60°C)
Cell Charge Temperature: 32°F (0°C) to 131°F (55°C)
NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the other items mentioned disabled if applicable. Consult your charger's manual or the manufacturer.

$209.70

Original: $699.00

-70%
Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery—

$699.00

$209.70

More Images

Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery - Image 2

Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery

Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery

 

  • LiFePO4 Chemistry - Deep Cycle Battery
  • Group 24: L10.25" x W6.75" x H9.00"
  • Low-Temperature cut-off (Charge Protection)
  • Built-in Smart Battery Management System (BMS)
  • Advanced BMS system with 20+ safety features built in
  • Over charge and over discharge protection
  • Over current and short circuit protection
  • High & low temperature disconnects
  • Max (4) in Series up to 48V
  • Max (16) in Parallel up to 20.48 kWh
  • 4,500+ Cycle life & Maintenance-free
  • 6 Year Manufacturer Warranty

Specifications 

Cell Configuration: 4S1P
Chemistry: LiFePO4
Current
Ah Capacity: 314Ah
Max Continuous Discharge Amps: 250A
Max Charge Current Amps: 250A
Max Discharge Peak Current Amps: 750A (5 Seconds)
Series | Parallel: Max (4) in Series, Max (16) in Parallel
Voltage
Voltage: 12.8V
Max Charge Voltage: 14.6V
Operating Voltage Range: 10.0 - 14.6V
Temperature
Charge Temp Range: 0°C (32°F) / 55°C (131°F)
Discharge Temp Range: -20°C (-4°F) / 60°C (140°F)
Storage Temp: 0°C (32°F) / 35°C (95°F)

Weights & Dimensions

Weight: 57 (LBS)
Dimensions
Length: 13.75" @ Base, 15.5" @ Handles (inches)
Width: 7.63" (inches)
Height: 10.0", 10.5' with Terminal Bolts (inches)
s)

Recommended Charge Settings 

To properly charge your Epoch Batteries, you will want to verify that any charging component in your system is capable of being programmed for the following specifications. Charging components can include, but are not limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.
Bulk/Absorption: 14.2V – 14.6V
Absorption Time: Two batteries in parallel connections require 30 minutes 200Ah
Float: 13.4V – 13.8V
Equalization: 14.4V/ Disabled
Temperature Compensation: 0/Disabled
Charge Rate: 50% of the battery or battery bank capacity
Battery Charge Temperature Range: 32°F (0°C) to 131°F (55°C)
Battery Discharge Temperature Range: -4°F (-20°C) to 140°F (60°C)
Cell Charge Temperature: 32°F (0°C) to 131°F (55°C)
NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the other items mentioned disabled if applicable. Consult your charger's manual or the manufacturer.

Product Information

Shipping & Returns

Description

Epoch Batteries 12V 314Ah (4.02kWh) - Eco Series LiFePO4 Battery

 

  • LiFePO4 Chemistry - Deep Cycle Battery
  • Group 24: L10.25" x W6.75" x H9.00"
  • Low-Temperature cut-off (Charge Protection)
  • Built-in Smart Battery Management System (BMS)
  • Advanced BMS system with 20+ safety features built in
  • Over charge and over discharge protection
  • Over current and short circuit protection
  • High & low temperature disconnects
  • Max (4) in Series up to 48V
  • Max (16) in Parallel up to 20.48 kWh
  • 4,500+ Cycle life & Maintenance-free
  • 6 Year Manufacturer Warranty

Specifications 

Cell Configuration: 4S1P
Chemistry: LiFePO4
Current
Ah Capacity: 314Ah
Max Continuous Discharge Amps: 250A
Max Charge Current Amps: 250A
Max Discharge Peak Current Amps: 750A (5 Seconds)
Series | Parallel: Max (4) in Series, Max (16) in Parallel
Voltage
Voltage: 12.8V
Max Charge Voltage: 14.6V
Operating Voltage Range: 10.0 - 14.6V
Temperature
Charge Temp Range: 0°C (32°F) / 55°C (131°F)
Discharge Temp Range: -20°C (-4°F) / 60°C (140°F)
Storage Temp: 0°C (32°F) / 35°C (95°F)

Weights & Dimensions

Weight: 57 (LBS)
Dimensions
Length: 13.75" @ Base, 15.5" @ Handles (inches)
Width: 7.63" (inches)
Height: 10.0", 10.5' with Terminal Bolts (inches)
s)

Recommended Charge Settings 

To properly charge your Epoch Batteries, you will want to verify that any charging component in your system is capable of being programmed for the following specifications. Charging components can include, but are not limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.
Bulk/Absorption: 14.2V – 14.6V
Absorption Time: Two batteries in parallel connections require 30 minutes 200Ah
Float: 13.4V – 13.8V
Equalization: 14.4V/ Disabled
Temperature Compensation: 0/Disabled
Charge Rate: 50% of the battery or battery bank capacity
Battery Charge Temperature Range: 32°F (0°C) to 131°F (55°C)
Battery Discharge Temperature Range: -4°F (-20°C) to 140°F (60°C)
Cell Charge Temperature: 32°F (0°C) to 131°F (55°C)
NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the other items mentioned disabled if applicable. Consult your charger's manual or the manufacturer.